Aiphone -IE-1SA - 2 Wire - 1 to 1 Audio Intercom
Installation Manual
Japanese Quality Audio only Intercom with a flush mount stainless steel outdoor station with a button that calls inside where a handset may be lifted to answer the call like a normal phone. A press button on the handset can open a pedestrian gate or front door fitted with an electric lock or an automatic driveway gate or garage door for letting visitors in without the occupant having to go outside.
Chime Volume Adjustment
The chime volume can be adjusted for the space its in or muted in case no-one wants to be disturbed.
Power Requirements
The handset requires 12VDC power, which comes from a transformer either next to the handset or away from the handset with a low voltage power cable run to it. The outdoor station requires no power connected as its power is passed through the 2 wires between the Handset the Outdoor Station.
The Lock Output
The lock output from this intercom is on the handset so requires an additional 2 wires run out to the gate. This can be directly wired to operate an automatic gate with no other interface or wired to release an electric latch ... READ MORE
Includes
IE-JA Outdoor station, IE-1ADU Handset. Transformer, extension chime and electric lock are chosen separately.
Wire Size verses Distance
Wire Distance is the length of the wire measured between the Indoor and Outdoor Stations, the IER-2 external chime and Indoor Station or between the Electric Lock and Indoor Station.
0.5mm dia. to 90m - 0.65 to 150m - 0.8mm dia. to 230m - 1.0mm dia. to 360m
If using the intercom to open an automatic driveway gate the cable size can be 0.5mm dia. up to 360m.
The wire distance between the transformer and Handset must be a maximum of 10m with 0.65mm dia. cable.
Note: If installing cable in the ground it must be in conduit and be a cable that is rated for use in the ground. Multi-stranded security cable or figure 8 cable is NOT suitable in the ground it must have a polythene sheath and if the diameter of the cable is less than 0.8mm it must be filled with gel to stop it corroding.
... more on Installing Low Voltage Cabling
Dimensions
Wiring Diagram
TotalQTYEach
$427.88$427.88
Delivery Location: